Language: Chinese line English

Photochemical reaction apparatus

  • OCRS-V type Photochemical Reaction
OCRS-V type Photochemical Reaction

OCRS-V type Photochemical Reaction

  • Product description: OCRS-V type Photochemical Reaction
  • INQUIRY


Description photochemical reaction apparatus

OCRS photochemical reaction apparatus is a multifunction factory reference to foreign imports on the basis of photochemical reaction apparatus, according to most customer needs, combined with the well-known laboratory practice, to develop a new generation of photochemical reactor. Cikuan OCRS   type multi-functional apparatus for use in research photochemical reaction of gas, liquid solid phase, the mobile system in a simulated ultraviolet, visible light, special analog illumination, whether loaded TiO2 photocatalyst photochemical reaction under such conditions. Meanwhile our company also can provide customers Tigong fibrous, arranged like substance reaction container and other special material, to address different substances in conventional reaction vessel placed within the reaction OCRS  utility photochemical reaction apparatus suitable for chemical synthesis, environmental and life sciences research, this system has a reasonable, simple structure, convenient operation, stable operation, to protect the human body, free combination, the unique flexibility to customize Advantage!

All the equipment is configured as followsSome components are optional:
(1) OCRS -based black-box set of subjects;
(2) high-pressure mercury electric control system, control high-pressure mercury lamp power: 100W 300W 500W 1000W of power.
(3) high pressure mercury lamp 100W 300W 500W 1000W each one
(4) long-arc xenon lamp (simulated sun) electrical control system, control xenon lamp power: 300W 500W 1000W of power.
(5) Metal Halide Lamp 250W 400W each one and the corresponding ballast system.
(6) were all quartz reaction tubes can be used 30ml quartz tube 8 , 50ml quartz tube 8.
(7) 30ml solid sealing plug 8.
50ml solid sealing plug 8.
(8) in vitro independent set of inflatable device can be controlled separately inflatable of the size.
(9) double-wide double-glazed quartz cold trap (an extension of the cooling water at the bottom of the cooling cycle) 2.
(10) factory production of OCRS -V-type eight-field-type photochemical reaction apparatus a special mixer.
(11) photolysis instrument supply pump a constant temperature reaction (the lowest limit of temperature -25 degrees). And the corresponding pipe and metal pipe fittings and other fixed number.
(12) water pipes, stainless steel valves, glass, number of valves.
(13) Stainless steel can be a mobile cart.

First, the main box
The main box is a series of photochemical reaction apparatus placed where light devices, has the following characteristics:
Box of size 480mm × 420mm × 900mm, weighs about 29kg.
Inside the black box in order to reduce light reflection.
After the upper cabinets with cooling fan board, cabinets after the central board has "flow switch", can be realized off (cooling water) water alarm. After the bottom plate has two holes for the cooling water pipes, pipe and cable to connect the controller through.
Cabinets on the left there are three special socket for the box of the motor, lights and the "flow switch" to use the output plug.

Second, mercury and mercury electric controller
Provide light for the 300W or 500W medium pressure mercury lamp of the normal operation of mercury lamps in ultraviolet light generated during the operation accounted for 40% total energy issue. Mercury lamp light in the opening 5 minutes until stable, turn off the lights need to wait 5 minutes after the order to restart. When you do need to bring sunglasses with UV protection of eye and skin damage.
Medium pressure mercury lamp of the optical parameters are as follows:
Mercury lamp spectral distribution and relative intensity as follows:

Table 2 Spectral distribution of medium pressure mercury lamp

Wavelength (nm)

250

313

365

400

510

620

720

Relative intensity%

20

85

100

30

20

40

80


Mercury lamp light-emitting part of the quartz tube, hand direct contact with pollutants, which affect the light intensity. Quartz commonly used outside a clean cotton cloth dampened with a small amount of alcohol, cleaning inside the use lotion.
Control panel with: the total power supply, lamp selection, lamp power supply, motors, light switches and the total time of launch and other settings, sub-time setting, lamp current meter, alarm instructions. Controller with fan heat.
Controller size is 245mm × 170mm × 180mm, weighs about 23kg.
Open the controller procedure is: select light lamp power → → → total power light starts, press start and then began a timing light.
Close control of procedures: the total lamp power → Electrical → → 5 minutes after power off the cooling water.
Controller on the back of a power input line and fuse holder.
Controller on the back of the main box for the cable plug with the corresponding interfaces.
In the main cable box connected with the controller error, or lower than normal water pressure for the cooling water, the alarm lamp will light and alarm sound, instruments unable to work.

Three, xenon lamp and xenon lamp electrical controller
Provide light for the 500W or 1000W xenon lamp normal and stable operation. Controller size is 245mm × 170mm × 180mm, weight 34kg. Control panel with the exception "light select" button, other buttons with the same mercury lamp controller. Xenon lamp spectral distribution and relative intensity similar to daylight.
Xenon lamp optical parameters are as follows:

Table 3 Dimensions xenon lamps and optical parameters

Power (W)

Starting current (A)

Operating Current(A)

Operating Voltage(V)

Effective arc length(MM)

Wiring

500

8.3

18±3

50

220±20

Single-ended leads

1000

12.4

30±3

60

220±20

Single-ended leads

Fourth, all quartz glass light protection or improvement of the cold trap
all improvement of the entire quartz glass light protection of the cold trap is not only high efficiency UV penetration, while working long hours away because the light source caused by temperature, ensuring access to light and reactive substances, only the experiment itself without outside influence .

Fifth, Photochemical special magnetic stirrer
OCRS –V type photochemical reaction apparatus dedicated mixer is a new eight-field dedicated magnetic stirring device can sample the full uniform light.
● Implementation of the multi-tube while simultaneously mixing the root function, which can place the eight test tubes (size 10ml, 30ml, 50ml free combination), each child can be in vitro variable speed magnetic stirring.
● excellent selection of main components of this machine, electric motors use DC power, stirring torque noise. Use the strongest magnet magnetic current, "Nd-Fe-spring" to do the rotor magnet, to ensure adequate sharp and torque.

Sixth, photochemical reaction temperature reactor supply pump
Temperature response supply pump, is to take mechanical forms of low-temperature liquid circulation cooling equipment. With high-temperature liquid, high-temperature water bath effect. Combination of OCRS  type photochemical reaction apparatus, for multi-state chemical reactions work. Is a new experimental device may be used instead of dry ice and liquid nitrogen temperature response do could be done as a low temperature sink Viscosity. Bottom with a strong magnetic stirring, mixing and internal circulation system with 2 to tank the temperature more uniform, can be done individually temperature, constant temperature circulating pump to provide constant temperature cold source use and. Such as bio-pharmaceuticals, chemical engineering, food engineering, that require high-precision sample from field sources. Widely used in hospitals, scientific research, experiments and identification of biological and other aspects of the work.



Baidu
sogou